Search Results Shortcode Test Page

Proceedings Of The 2nd International Masonry Conference

PROCEEDINGS OF THE BRITISH MASONRY SOCIETY MASONRY (4) PROCEEDINGS OF THE SECOND INTERNATIONAL MASONRY CONFERENCE No. 4, July 1990, Edited by: H W H West 39 Papers, 159 pp, published […]

Proceedings Of The 3rd International Masonry Conference

PROCEEDINGS OF THE BRITISH MASONRY SOCIETY MASONRY (6) PROCEEDINGS OF THE THIRD INTERNATIONAL MASONRY CONFERENCE No. 6, March 1994, Edited by: H W H West Contents page I Properties of […]

Proceedings Of The 4th International Masonry Conference

Proceedings Of The British Masonry Society Masonry (7) Proceedings Of The Fourth International Masonry Conference No. 7, 1995, Edited by: H W H West Contents Volumes 1 and 2 Volume […]

Proceedings Of The 5th International Masonry Conference

ISSN: 0950-9615 British Masonry Society Proceedings No.8 ALL papers Proceedings of the 5th International Masonry Conference PROCEEDINGS OF THE BRITISH MASONRY SOCIETY MASONRY (8) PROCEEDINGS OF THE FIFTH INTERNATIONAL MASONRY […]

Proceedings Of The 6th International Masonry Conference

PROCEEDINGS OF THE SIXTH INTERNATIONAL MASONRY CONFERENCE COMPLETE No. 9, November 2002, Edited by: G Thompson Contents: Non-Linear Analysis of Masonry Shear Walls P G Asteris and A D Tzamtzis […]

Proceedings Of The 7th International Masonry Conference

Proceedings of the British Masonry Society (10) Complete Proceedings of the 7th International Masonry Conference PROCEEDINGS OF THE SEVENTH INTERNATIONAL MASONRY CONFERENCE COMPLETE No. 10, November 2006, Edited by: G […]

The Shear Strength of Prestressed Brickwork Beams

This is the excerpt individual to each Download page this written by Keith

The Prism Test as a Measure of Masonry Strength — A Theoretical Analysis

Author N. G. SHRIVE The University of Calgary Abstract In many countries, stack-bonded prisms may be used to determine the compressive strength of masonry for design purposes. The results depend […]

The Structural Performance of Cavity Wall Ties

Author R. C. DE VEKEY and W. J. REED Building Research Establishment, Garston, Watford, UK Abstract Until recently virtually all cavity wall ties were of three types: (1) the butterfly […]

Wide Cavity Walls: Effect of Tie Density on Performance Under Vertical Load

Author S. K. ARORA Building Research Station Abstract The results of vertical load tests on 25 walls with 150 mm cavities are reported. Leaves of autoclaved aerated concrete blocks, lightweight […]

The Effect of the Absorption Characteristics of the Brickwork Background on the Adhesion of Renderings

Author I. H. MURRAY Building Research Establishment, Scottish Laboratory Abstract Loss of adhesion between render and brick is one major reason for the cause of rendering failure. Information is needed […]

Drilled-in Inserts in Masonry Construction

Author M.HATZINIKOLAS Alberta Masonry Institute J. LONGWORTH and J. WARWARUK The University of Alberta Abstract Drilled-in inserts of various types were tested under shear, direct tension and combined shear and […]