Lateral Strength of a Dry-Stack Wall System
Author
H. C. UZOEGBO and J. V. NGOWI School of Civil and Envir. Engg., University of the Witwatersrand, South Africa
Abstract
Three full-scale dry-stack interlocking masonry wall specimens were tested under lateral loading with three different spans of 1.5m, 3m and 6m. Further tests on six scale models (wallettes) were subjected to flexural bending parallel and perpendicular to the bed joint. The failure load, mid-span deflection, and failure mode were evaluated in each test. The test results were used as a basis for the development of an analytical expression to predict the lateral load carrying capacity of the dry-stack masonry. Comparison between the experimental and computed results shows good correspondence.
Key words
dry-stack masonry, interlocking block, fiexural strength, lateral loadAccess to this paper
Members: you need to log-in to access [download] the full paper.Non-members: You can access [download] this document by paying a small fee on-line - but why not consider the benefits of membership?
Price
£ 12.00 
*MEMBERS* Login to access the full paper!
 
Navigation trail:
IMS Home / Publications / Masonry Internati... / Masonry Internati... / Volume 17 / Lateral Strength...

