Behaviour of LECA Masonry under Restrained Shrinkage
Author
T. KVANDE* and K.V. H0ISETH** * Norwegian Building Research Institute ** MARINTEK Department of Structural Engineering
Abstract
The purpose of this investigation was to study the shrinkage behaviour of Light Expanded Clay Aggregate (LECA) masonry walls restrained at the foundation. To measure the effect of shrinkage reinforcement, the investigation comprised five restrained LECA walls with different amounts of reinforcement. As references, two walls resting on "ideal" sliding layers and three single LECA blocks were tested. Even though no cracking of LECA blocks was observed in the restrained specimens during the test period of 1 1/2 years, the test results indicate that the amount and position of the shrinkage reinforcement influence the magnitude of the horizontal shrinkage. The least horizontal shrinkage was obtained on the wall with most reinforcement (A/Au* 0.67%). The effect of the reinforcement seems, however, to be limited. There was no significant difference between the vertical shrinkage of the restrained walls and the shrinkage of the other specimens. Design values for shrinkage may therefore be derived from tests of single untreated LECA blocks.
Key words
Access to this paper
Members: you need to log-in to access [download] the full paper.Non-members: You can access [download] this document by paying a small fee on-line - but why not consider the benefits of membership?
Price
£ 12.00 
*MEMBERS* Login to access the full paper!
 
Navigation trail:
IMS Home / Publications / Masonry Internati... / Masonry Internati... / Volume 15 / Behaviour of LECA...